Available on backorder
Portable Multi parameter Water Quality Meter – Model: PH-900P
Features:
PH Mode:
- 1 to 5 points push-button calibration with auto-buffer recognition.
- Selectable pH buffer standard ( USA / NIST / DIN ) or using the custom calibration solutions.
- Automatic electrode slope display helps user decide whether to replace sensor. ORP Mode:
- 1 point offset calibration allows adjusting the displayed value to known standard.
- Relative and absolute mV measurements provide the accurate ORP readings. Ion Concentration Mode:
- 2 to 5 points calibration including the eight concentration points can be selected.
- MV measurement mode can be used for checking the performance of current ion selective electrode.
- Automatically recognize ion electrodes, does not need to specify the type of ion.
- Direct ion concentration readout simplifies the elaborate measurement process.
- Selectable concentration unit including the ppm, mg/L, mol/L, mmol/L for different applications. Conductivity/TDS/Salinity/Resistivity Mode:
- 1 to 5 points calibration with automatic calibration solution recognition.
- Selectable cell constant ( 0.1/1/10), normalization temperature ( 20°C or 25°C ),TDS conversion factor, seawater and practical salinity measurement modes.
- Linear or pure water compensation improves the measurement accuracy. Dissolved Oxygen Mode:
- 1 or 2 points calibration using the air-saturated water and zero oxygen solution.
- Manual salinity and barometric pressure compensation ensure accurate readings. Other Features:
- Automatic Temperature Compensation provides accurate measured values over the entire range.
- Calibration Due Reminder prompts user to calibrate the meter regularly.
- Stability indicator automatically shows current measurement status.
- Auto-Hold function freezes stable reading for easy viewing and recording.
- Manual temperature calibration corrects the temperature deviation.
- Selectable temperature unit (°C or °F ) meets different application requirements.
- Automatic electrode diagnosis shows zero point offset and electrode slope.
- Help message as a operational guide that helps user quickly using the meter.
- System menu allows setting the 15 parameters, including the resolution, number of calibration points, stability condition, measurement unit, etc.
- Reset feature automatically resumes all settings back to factory default options.
- Expanded memory stores and recalls up to 500 readings.
Features:
PH Mode:
- 1 to 5 points push-button calibration with auto-buffer recognition.
- Selectable pH buffer standard ( USA / NIST / DIN ) or using the custom calibration solutions.
- Automatic electrode slope display helps user decide whether to replace sens or. ORP Mode:
- 1 point offset calibration allows adjusting the displayed value to known standard.
- Relative and absolute mV measurements provide the accurate ORP readings. Ion Concentration Mode:
- 2 to 5 points calibration including the eight concentration points can be selected.
- MV measurement mode can be used for checking the performance of current ion selective electrode.
- Automatically recognize ion electrodes, does not need to specify the type of ion.
- Direct ion concentration readout simplifies the elaborate measurement process.
- Selectable concentration unit including the ppm, mg/L, mol/L, mmol/L for different applications. Conductivity/TDS/Salinity/Resistivity Mode:
- 1 to 5 points calibration with automatic calibration solution recognition.
- Selectable cell constant ( 0.1/1/10), normalization temperature ( 20°C or 25°C ),TDS conversion factor, seawater and practical salinity measurement modes.
- Linear or pure water compensation improves the measurement accuracy. Dissolved Oxygen Mode:
- 1 or 2 points calibration using the air-saturated water and zero oxygen solution.
- Manual salinity and barometric pressure compensation ensure accurate readings. Other Features:
- Automatic Temperature Compensation provides accurate measured values over the entire range.
- Calibration Due Reminder prompts user to calibrate the meter regularly.
- Stability indicator automatically shows current measurement status.
- Auto-Hold function freezes stable reading for easy viewing and recording.
- Manual temperature calibration corrects the temperature deviation.
- Selectable temperature unit (°C or °F ) meets different application requirements.
- Automatic electrode diagnosis shows zero point offset and electrode slope.
- Help message as a operational guide that helps user quickly using the meter.
- System menu allows setting the 15 parameters, including the resolution, number of calibration points, stability condition, measurement unit, etc.
- Reset feature automatically resumes all settings back to factory default options.
- Expanded memory stores and recalls up to 500 readings.
- Built-in real-time clock stamps stored data to meet GLP standard.
- Stored data can be transferred into computer by USB communication interface.
- Multi-mode power scheme (battery, power adapter, USB port) ensures that use the meter smoothly.
$1.00
Measurement Modes:
PH-900P multi-parameter portable meters are capable of measuring up to 9 water quality parameters. Each meter includethe different measurement modes. Test items: pH, ORP, Ion, Conductivity, TDS, Salinity, Resistivity and Dissolved Oxygen.
Accessories:
- Temperature probe.
- Calibration solutions.
- Batteries.
- Carrying case.
- pH, conductivity and dissolved oxygen electrodes
Technical Parameters:
| Model | PH-900P | |
| PH | Range | -2.000〜20.000pH |
| Accuracy | ±0.002pH | |
| Calibration Points | 1〜5 points | |
| Calibration Solutions | USA, NIST, DIN or User-defined | |
| ORP | Range | -1999.9-1999.9mV |
| Accuracy | ±0.2mV | |
| Calibration Points | 1 point | |
| Measurement Modes | mV and Relative mV | |
| Ion | Range | 0〜19999ppm,mg/L, mol/L (Depending on range of ISE) |
| Accuracy | ±0.5% F.S (Monovalent), ±1% F.S (Divalent) | |
| Calibration Points | 2~5 points | |
| Calibration Solutions | 0.001, 0.01,0.1, 1, 10, 100, 1000, 10000ppm, mol/L, mg/L | |
| Conductivity | Range | 0-20.00, 200.0, 2000pS/cm, 20.00, 200.0mS/cm |
| Accuracy | ±0.5% F.S | |
| Calibration Points | 1~5 points | |
| Calibration Solutions | 10pS/cm, 84pS/cm,1413pS/cm,12.88mS/cm,111.8mS/cm | |
| Temperature Coefficient | 0.0-10.0%/°C | |
| Compensation Modes | Linear or Pure Water | |
| Cell Constant | K=0.1, 1, 10 or User-defined | |
| Normalization Temperature | 20°C or 25°C | |
| TDS | Range | 0~100ppt (Max. 200ppt, depending on factor setting) |
| Accuracy | ±1% F.S | |
| TDS Factor | 0.1-1.0 (Default 0.5) | |
| Salinity | Range | 0-1 Oppt (Max. 80ppt) |
| Accuracy | ±1% F.S | |
| Measurement Modes | Seawater or Practical Salinity | |
| Resistivity | Range | 0-100MQ |
| Accuracy | ±1% F.S | |
| Resolution | 0.01,0.1, 1 | |
| Dissolved
Oxygen |
Concentration Range | 0.00〜20.00mg/L (or ppm) |
| Accuracy | ±0.2mg/L | |
| Calibration Points | 1 〜2 points | |
| Pressure Correction | 60.0-112.5kPa, 450~850mmHg | |
| Salinity Correction | 0~50g/L | |
| % Saturation of Oxygen | 0.0-200.0% | |
| Accuracy | ±2.0% | |
| Others | Temperature Compensation | 0~100oC, 32〜212OF, Manual or Automatic |
| Stability Conditions | Low or High | |
| Calibration Due | 0 to 31 days | |
| Memory | Stores up to 500 data sets | |
| Output | USB Communication Interface | |
| Power Requirements | 3×1.5V “AA” batteries (Standard) or DC5V power adapter (Optional) | |
| Dimensions | 185*88‘32mm | |
| Package Size(W‘D*H) | 475‘155‘350mm | |
| Net Weight | 300g | |
| Gross Weight | 2kg | |







Reviews